• Chỉ mục bởi
  • Năm xuất bản
LIÊN KẾT WEBSITE

Characterization of indoor and ambient air quality in modern commercial and recreational complex buildings in Hanoi

Anh Le (57446769200) | Van Minh (57210747045); Hoang Faculty of Environmental Sciences, University of Science, Vietnam National University, Hanoi, 334 Nguyen Trai, Thanh Xuan, Hanoi, Viet Nam|

Atmospheric Environment Số , năm 2022 (Tập 291, trang -)

ISSN: 13522310

ISSN: 13522310

DOI: 10.1016/j.atmosenv.2022.119405

Tài liệu thuộc danh mục:

Article

English

Từ khóa: Hanoi; Viet Nam; Air quality; Buildings; Fog; Indoor air pollution; Particles (particulate matter); Xylene; benzene; ethylbenzene; fuel; gasoline; nitric oxide; ortho xylene; toluene; xylene; Ambient air; Ambient air quality; BTEX; Commercial building; Complex buildings; Gaseous pollutants; Indoor air quality; Mass concentration; Particulate Matter; Recreational buildings; air quality; ambient air; building; indoor air; particulate matter; air conditioning; air monitoring; air quality; air sampling; ambient air; Article; artificial ventilation; carbon emission; concentration ratio; cross-sectional study; particulate matter 10; particulate matter 2.5; pollutant; practice guideline; Viet Nam; Floors
Tóm tắt tiếng anh
The paper provides new information on the correlation between indoor and ambient air quality in selected commercial and recreational buildings, representing a cross-section of metropolitan building complexes in Hanoi, Vietnam. Air sampling carried out simultaneously at fixed locations within the case study directed the varying behavior across different zones and thus highlighted the relationship between parking basements, commercial floors, and ambient air sites. The fractions of coarse and fine particles were analyzed to identify the associated emission sources on a short-term basis. The elevated 8-h average levels of CO in underground parking zones (11–22 mg/m3) were significantly higher than those measured on commercial floors (0.5–0.9 mg/m3) and relatively ambient air (0.8–1 mg/m3) and exceeded the recommended exposure limit of 10 mg/m3 in the corresponding guidelines. Short-term averages of SO2 mass concentration (112–225 μg/m3) remained below the limits of 500 μg/m3 concerning health exposure in existing standards. The correlation of daily NO2 patterns was analyzed accordingly in relation to the operation of the individual building, the central ventilation mechanism, and the penetration of outside air, which is usually conditioned by traffic emission. The mass concentrations of PM10 and PM2.5 measured outdoors (21–32 μg/m3 and 12–14 μg/m3) and in parking basements (28–67 μg/m3 and 15–27 μg/m3) were generally higher than those recorded indoors at ground levels (1–29 μg/m3 and 1–20 μg/m3), frequently reaching the reference exposure values (15 μg/m3 and 5 μg/m3) for public health concerns. The determined levels and profiles of benzene, toluene, ethylbenzene, (m + p)-xylene, and o-xylene corresponding to the relative ratios of T/B and X/E revealed the responsible emissions from gasoline-fueled vehicles in parking basements and the influence of associated local traffic. © 2022 Elsevier Ltd

Xem chi tiết