• Chỉ mục bởi
  • Năm xuất bản
LIÊN KẾT WEBSITE

Trace-Level Determination of Oxolinic Acid and Flumequine in Soil, River Bed Sediment, and River Water Using Microwave-Assisted Extraction and High-Performance Liquid Chromatography with Fluorimetric Detection

Dinh Q.T. Environmental Engineering and Management Research Group, Ton Duc Thang University, Ho Chi Minh City, Viet Nam|
Chevreuil M. | Blanchard M. | Teil M.-J. | Alliot F. CARE, Ho Chi Minh City University of Technology (HCMUT), Vietnam National University Ho Chi Minh City (VNU-HCM), Ho Chi Minh City, Viet Nam| Moreau-Guigon E. EPHE, PSL Research University, UMR 7619 METIS (UPMC Univ. Paris 06/CNRS/EPHE), Paris, France| Nguyen T.A. Faculty of Environment and Labour Safety, Ton Duc Thang University, Ho Chi Minh City, Viet Nam|

Soil and Sediment Contamination Số 3, năm 2017 (Tập 26, trang 247-258)

DOI: 10.1080/15320383.2017.1276154

Tài liệu thuộc danh mục: ISI, Scopus

Final

English

Từ khóa: Antibiotics; Chromatography; High performance liquid chromatography; Liquid chromatography; Liquids; Phase separation; Rivers; Sediments; Soils; Water; Water resources; Analytical procedure; Fluorimetric detection; Limits of detection; Microwave-assisted extraction; Polymeric sorbents; River water samples; Solid-phase extraction; Trace-level determination; Extraction
Tóm tắt tiếng anh
This work presents the optimization of analytical procedures for the determination of two antibiotics, oxolinic acid (OA) and flumequine (FL), in bed sediment, river water, and soil samples. Three extraction methods (microwave-assisted extraction (MAE), ultrasonication, and reflux) were tested, and the highest recoveries were obtained with MAE (94 ± 3% and 95 ± 3% for OA and FL, respectively). A solid-phase extraction (SPE) clean-up step was optimized by comparing two polymeric sorbents: Oasis HLB and Oasis MAX. The final extracts were analyzed by liquid chromatography with fluorimetric detection. Limits of detection (LOD) obtained for OA and FL in soil and sediment ranged from 0.3 to 0.5 µg kg−1. Meanwhile, a novel SPE procedure was also implemented for OA and FL determination in river water samples. It also relied on the use of Oasis MAX, and recovery rates were in the range 90–94%; LODs were 2 ng L−1 for both OA and FL. These methods were applied for the analysis of samples taken in the Seine River basin (France). The obtained results demonstrated the widespread occurrence of OA and FL, at ng L−1 and µg kg−1 levels in water and sediment/soil, respectively, and their persistence in the environment. © 2017 Taylor & Francis Group, LLC.

Xem chi tiết